Symptom
Stains on Window Trim and Glass
|
Causes
Seepage of Trapped Water Containing Dissolved Rust and Minerals Salts
|
 |
Symptom
Rusted Steel Above Windows
|
Causes
Moisture Trapped by Inadequate or Failed Flashing System
|
 |
Symptom
Sealant Debonding at Windows
|
Causes
Rusting of Steel Support at Bond Point
|
 |
Symptom
Tide Marks on Brick Surface
|
Causes
Periodic Saturation of Brick Caused by Trapped Water
|
 |
Symptom
Recrystallization of Dissolved Salts on Brick Surface
|
Causes
Trapped Moisture Solubilizes Free Lime within Masonry
|
 |
Symptom
Moss and/or Algae on Mortar Surfaces
|
Causes
Continuous Retention of Moisture
|
 |
Symptom
Sealant Deterioration
|
Causes
Sunlight/Atmosphere - Improper Materials Specification
|
 |
Symptom
Sealant Pouting
|
Causes
Improperly Designed/Installed Expansion Relief System
|
 |
Symptom
Sealant Debonding from Brick
|
Causes
Improper Sealant Bond Break Specification or Installation
|
 |
Symptom
Sill Displacement
|
Causes
Inadequate Flashing/Wall Drainage System
|
 |
Symptom
Horizontal Joint Cracking
|
Causes
Inadequate Expansion Relief System/Oxide Jacking
|
 |
Symptom
Vertical Displacement
|
Causes
Inadequate Expansion Relief System
|
 |
Symptom
Gross Masonry Failure
|
Causes
Inadequate Expansion Relief System/Other
|